Product: Valve Oblique Landing pattern
Brand: SFFECO
Origin: UK
Model: SFD-K65-OLVST
Type: Oblique Globe Pattern Landing Valve
Standard Certificate: BS5041-1
Body: Copper alloy, |
Inlet: Flanged or BSP Screwed
Outlet: Female instantaneous to BS336
Application: Fire Hydrant, Wet Riser & Dry Riser Systems
From sound to comfort — Aurora Pro is designed with all-day use in mind.
Block out unwanted noise and focus only on your music.
Enjoy up to 40 hours of continuous use on a single charge, with 5 hours of playback from just a 10-minute charge.
Fast and stable connection, supporting up to a 30-meter range.
Memory-foam ear cushions and a lightweight frame ensure zero pressure even after long hours of use.
On wet or dry riser firefighting systems, the Valve Oblique Landing pattern globe type with a male screwed inlet is a fire hydrant landing valve that offers a handy hose connection point. The outlet is positioned for practical hose attachment and operation during emergency response thanks to its tilted body structure. Industry-standard models often come with an immediate hose output and a threaded male inlet; depending on the type, BS 5041 or BS 336 configurations are available.
When dependable floor-level access to pressurized firefighting water is needed, this oblique landing valve is especially appropriate for building fire prevention systems. The globe-pattern architecture is intended to provide reliable shut-off operation and regulated water flow.
Product: Valve Oblique Landing pattern
Brand: SFFECO
Origin: UK
Model: SFD-K65-OLVST
Type: Oblique Globe Pattern Landing Valve
Standard Certificate: BS5041-1
Body: Copper alloy, |
Thickness: > 3mm
Handwheel: Grey cast iron,
Blank cap: Copper alloy
Inlet: Flanged or BSP Screwed
Outlet: Female instantaneous to BS336
Surface: Red or Yellow Painting
Test Pressure: 22.5 bar
Flow Rates: More than 8.5 L/s
Fully open: 4.5 turns
Application: Fire Hydrant, Wet Riser & Dry Riser Systems
The datasheet of the chosen manufacturer should be consulted to confirm the precise materials, inlet threads, outlet arrangements, pressure ratings, and certification of the several commercial oblique pattern globe type landing valve models that are offered in 2½-inch configurations.
Simple Fire Hose Attachment: The landing valve oblique type's angled outlet offers a useful connecting position that makes it easier for firefighters to handle and attach hoses in an emergency.
Effective Water Distribution: Effective water delivery to the firefighting area is supported by a suitably designed oblique type landing valve, which creates a controlled pathway from the riser to the linked fire hose.
Operational Accessibility: Without the need for complicated working equipment, the fireman may handle the valve from an accessible position thanks to its handwheel-operated design.
Dependable Shut-Off: Positive flow control and shut-off when the fire hose connection is not needed are supported by globe-pattern valve construction.
Extended Service Life: These valves are frequently made of gunmetal and copper-alloy, which provide durability and corrosion resistance appropriate for harsh fire safety conditions.
Providing a special fire hose connection to the building's fire riser system is one of the main purposes for valve oblique landings. It enables emergency workers to regulate the water flow from the pressured riser and connect a suitable hose at specified firefighting levels.
When the outlet must be positioned at an angle for better hose access and operator convenience, an oblique pattern hydrant landing valve is very helpful.
Instead than assuming the handwheel operating direction from the valve body style, the manufacturer's markings and installation documents should be consulted for any landing valve. The installer should verify the valve's full-open and full-closed positions during commissioning and make sure it runs smoothly without using too much force.
The manufacturer's operating instructions should be followed during installation and testing since some oblique landing valve products require many handwheel rotations between fully open and completely closed positions.
For reliable fire safety, landing valve installation must be done correctly. The valve should be installed at the designated fire site, with the hose outlet positioned for unhindered firefighter access and the inlet connection correctly matched to the riser pipework.
Before assembling a screwed oblique landing valve, installers should confirm the proper thread standard, nominal size, outlet connection, pressure rating, and sealing technique. Compatibility with the receiving female connection is especially crucial when a male threaded inlet is specified.
The approved fire protection designs, product instructions, and relevant project requirements should all be followed throughout the final installation. For pertinent landing valve and hose connection designs, BS 5041 and BS 336 are frequently cited.
When selecting a screw oblique landing valve, consider:
The Valve Oblique Landing pattern globe type is a practical choice for fire hydrant and riser systems where accessible hose connection, controlled water flow and dependable shut-off are required.
Its angled configuration can improve hose accessibility, while a male screwed inlet provides a straightforward connection option for compatible fire-riser pipework. Quality versions are available with recognized fire-system standards and certification, giving engineers and building owners a more dependable option for critical fire protection installations.
A Valve Oblique Landing pattern globe type with a male screwed provides a dependable hose connection and flow-control point for building fire protection systems. Its angled configuration, globe-pattern operation and threaded inlet make it suitable for a wide range of wet riser, dry riser and fire hydrant applications.
Selecting the correct size, connection standard, pressure rating and certified configuration is essential to ensure the valve integrates correctly with the overall fire safety system.
| Size | Any |
| Model | Any |
| Origin | USA or China |
| Warranty | As per policy |