Product Type: Fire Hydrant System
Origin: China
Pump Type: Vertical Multistage
Compliance: NFPA 20
Flow rate: 20 - 50 GPM
Pressure: 9-14 bar
Head: Up to 190 Meter
Temperature Range: -15°C to +120°C (Hot Water Version)
Power Supply: 380–415V / 460V, 3 Phase, 50/60 Hz
Wetted Parts: Stainless Steel
IP Rating: IP55
From sound to comfort — Aurora Pro is designed with all-day use in mind.
Block out unwanted noise and focus only on your music.
Enjoy up to 40 hours of continuous use on a single charge, with 5 hours of playback from just a 10-minute charge.
Fast and stable connection, supporting up to a 30-meter range.
Memory-foam ear cushions and a lightweight frame ensure zero pressure even after long hours of use.
The Fire Hydrant Jockey Pump Water System is designed to maintain the required pressure in a pressurized fire water system during normal standby conditions and help prevent unnecessary operation of the main fire pump caused by minor leakage or routine pressure loss. Maintaining stable pressure is essential for a reliable fire protection network.
A jockey pump is a dedicated pressure-maintenance pump used alongside the main fire pump. When system pressure falls within the jockey pump's configured start range, the pump supplies a relatively small amount of water to restore pressure. This allows the main fire pump to remain available for genuine fire-flow demand rather than responding to every small pressure fluctuation.
The system can be configured with an electric pump, controller, pressure sensing arrangement, valves and associated piping according to the fire protection system design.
Product Type: Fire Hydrant System
Origin: China
Pump Type: Vertical Multistage
Compliance: NFPA 20
Flow rate: 20 - 50 GPM
Pressure: 9-14 bar
Head: Up to 190 Meter
Temperature Range: -15°C to +120°C (Hot Water Version)
Motor Power: 5.5 KW
Power Supply: 380–415V / 460V, 3 Phase, 50/60 Hz
Operation: Advance
Wetted Parts: Stainless Steel
IP Rating: IP55
Maintains Fire System Pressure: The primary purpose of a Fire Jockey Pump Hydrant System is to keep the fire protection piping at the required standby pressure. This helps the system remain ready for emergency operation.
Reduces Unnecessary Main Pump Starts: Small leaks and normal pressure losses can cause pressure fluctuations.
Automatic Pressure Maintenance: The controller continuously works with the pressure-sensing arrangement. When pressure reaches the configured cut-in level, the jockey pump can start and restore system pressure.
Supports Fire Pump Readiness: By maintaining standby pressure, the Jockey Pumps for Fire Pump Water System support the overall readiness of the main fire protection pumping arrangement.
Convenient Monitoring: Depending on controller selection, operators can monitor pressure, pump status, motor operation, alarms and other operating information.
The jockey pump controller is responsible for managing the pump's operating sequence. It receives pressure information through the sensing arrangement and controls pump starting and stopping according to configured pressure limits.
A jockey pump electric pump is typically driven by an electric motor and controlled through a dedicated pressure-maintenance controller.
This arrangement provides a practical solution for automatic pressure maintenance without requiring a diesel engine or fuel-storage system for the jockey pump itself.
The jockey pump electrical arrangement should be matched to the selected motor and controller. Important considerations include:
The electrical design should be completed by qualified personnel based on the equipment manufacturer's requirements and applicable codes.
The cost of jockey pump equipment depends on several factors, including:
Therefore, the correct price should be determined after confirming the required flow, pressure, motor rating and system configuration.
A properly designed Fire Hydrant Jockey Pump Water System provides an important pressure-maintenance function within a complete fire protection installation. It helps keep the network pressurized during standby conditions while reducing unnecessary operation of the main fire pump caused by minor pressure losses.
The Fire Hydrant Jockey Pump Water System is an important pressure-maintenance solution for modern fire protection networks. By automatically compensating for small pressure losses, the jockey pump helps keep hydrant and sprinkler piping ready for emergency demand while reducing unnecessary starts of the primary fire pump.
For dependable performance, the jockey pump, controller, pressure settings, pump capacity, electrical arrangement, sensing line and associated valves should be selected according to the hydraulic design, equipment specifications and applicable fire protection requirements. NFPA materials also identify dedicated jockey-pump arrangements, sensing lines and suitable isolation/check-valve provisions as important elements of the installation.
| Size | Any |
| Model | Any |
| Origin | USA or China |
| Warranty | As per policy |
Whether you need an audit, design consultation, maintenance contract, or a complete electrical solution, our team is ready to help.
✅ Over 20 Years of Industry Leadership
✅ 81+ Experts & Engineers
✅ 1,000+ Projects Delivered
✅ Trusted by Top Brands & Government Projects
✅ 24/7 Customer Support & Service
✅ Serving Industries Across Bangladesh